Qualitrol STB000 Main Tank and LTC Smart Transformer Dehydrating Breather

Remove moisture from entering oil-filed transformers or LTC conservators
 

As a transformer operates, oil expansion and contraction cause a transformer to breathe in humidity from the atmosphere that may age a transformer’s bladder, oil, and insulation system over time. This unnecessary aging to the transformer reduces the overall life of the asset making it difficult to provide reliable power leading. This can lead to additional costs for transformer maintenance or even premature transformer failure.

The Qualitrol STB000 Smart Transformer Breather removes moisture from the air that enters oil-filled transformers or Load Tap Changers (LTC) conservators. Moisture is trapped in silica gel desiccant located within the dehydrating breather.  The Qualitrol STB000 is automated to regenerate the silica gel desiccant at a user-selectable time interval using either of the industry’s leading technology – Parts Per Million (PPM) or Relative Humidity (RH) thresholds.

Unnecessary truck rolls or substation maintenance is avoided due to the Qualitrol STB000 Smart Transformer Breather’s internal heather unit that drives out moisture on the transformer exhale cycle allowing the silica gel to regenerate.

Even the smallest amounts of moisture in a power transformer can have varying degrees of problems ranging from limited output to failure.  The Qualitrol STB000 represents real cost savings, in addition to customization and easy install.

Merkmale

  • Reduzieren Sie die Wartungskosten durch erlernte Transformator Atmungsmuster und selbstregenerierendes Trocknungsmittel
  • Universal algorithm determines the best regeneration style based on the breathing pattern of the transformer. The STB000 automatically shifts to a time-based regeneration if it is installed on a tank that does not breathe, such as LTC application, eliminating the need to carry two models in your inventory
  • All units have standard C5M coating and carry a 5-year warranty
  • Multiple communication options including 4-20 mA, RS-485 MODBUS and local USB port provide allow for trending of moisture readings and regeneration cycles
  • New test button option allows for an easy diagnostic check of breather functions in the field
  • External LED indication gives current status of unit including active regeneration
  • Öltrocknungsmittel in der Grösse von 30'000 Litern/ 8'000 Gallonen

Optionen

  • Polar Modelle bieten zusätzliche interne Heizungen, die harten Temperaturen bis  zu -60 ° C standhalten
  • Offshore Xtreme ™ -Modelle enthalten Materialsets, die speziell für den Einsatz in rauen Meeresumgebungen entwickelt wurden
  • Mehrere Montageoptionen für neue oder nachträgliche Installation verfügbar
  • Enthält ein Magnetventil, das während des Regenerationsprozesses schließt, um sicherzustellen, dass keine Feuchtigkeit in den Transformator eindringt

Gruppe Created with Sketch. Applications

The Qualitrol STB series smart transformer dehydrating breather removes moisture from air entering oil-filled transformers or LTC conservators. The breather is automated to regenerate the silica gel desiccant at a user selectable time interval, relative humidity (RH) or PPM thresholds. Regenerating the silica gel automatically reduces unnecessary breather maintenance costs over time. Alarms and digital communications allow for remote monitoring of moisture levels and breather status. Recommended for use on Medium/Large Transformers with a voltage of 1.38kV and above.

Vergleichen Sie mit ähnlichen Produkten

Basic

Traditionelle Entlüfter auf dem Markt

Nutzt Silikagel, um atmosphärische Luft zu trocknen, während der Transformator atmet

Geringe Anschaffungskosten, aber die damit verbundenen Wartungskosten überwiegen im Laufe der Zeit

Es ist keine alarmierende Fähigkeit oder Fehlererkennung verfügbar, weshalb man sich auf menschliche Interaktion für die Wartung und Pflege verlassen muss

Bei Verwendung von kobalthaltigem Silikagel können wiederkehrende Trockenmittelentsorgungskosten anfallen

Erfahren Sie mehr
Erweitert

Andere automatische Luftentfeuchter auf dem Marktplatz

Verwenden Sie keine farbwechselnden Trocknungsmittel (Farbwechsel-Silikagele ermöglichen dem Benutzer eine sekundäre visuelle Anzeige der Regeneration)

Einige verwenden keine Drucksensor- und Magnetventiltechnologie, um Atemverschiebungen innerhalb des Transformators zu erkennen (Dies verhindert, dass flüssiges Wasser versehentlich in den Transformator gesaugt wird)

May not have additional smart breather options for harsh environmental conditions

Erfahren Sie mehr
Insgesamt
Qualitrol STB000 main tank LTC smart breather power transformers moisture

Qualitrol STB000 Main Tank and LTC Smart Transformer Dehydrating Breather

Keine Notwendigkeit für unnötige Wartung oder Ersatz von Silikagel im Feld

Alarmierungs- und Fehlererkennungsfunktion; keine Notwendigkeit, sich auf menschliche Interaktion zu verlassen

Nutzt ein Farbwechsel-Silikagel als ein sekundäres Anzeichen, dass die Regeneration stattgefunden hat, um Ruhe zu geben

Erkennt Ein- und Ausatemphasen, um zu verhindern, dass überschüssige Feuchtigkeit in den Transformator gesaugt wird

Erfahren Sie mehr
Sie könnten auch interessiert sein
Dieses Produkt funktioniert gut mit